Electrotechnique
Influence du courant de soudage sur la densité de courant , la température et la densité électrique.
l'objectif de notre travail est l'étude par simulation numérique de l'influence des courants de soudages sur la distribution des tensions, la densité de courant et la densité d'électron en fonction de la température et la distance inter-électrodes. Voir les détails
Mots clés : soudage TIG, élements finis, arc libre
An Improved Method for Bearing Faults diagnosis
Envelope analysis is especially suitable for faultdiagnosis inducing periodic shocks or amplitude modulations suchas gears and bearings and has been applied widely for mechanicalfault detections over the last few decades. However, a criticallimitation of this technique is that it requires a prior knowledge onfiltering band. Due to this drawback, detecting machine defects atthe incipient stage when defect-characteristic components areweak in amplitude and without a distinctive spectral pattern posesa challenge to the conventional enveloping spectral analysistechnique .In order to overcome this limitation, this work gives anew signal processing approach for bearing faults diagnosis basedon Hilbert Transform (HT) and Fast Fourier Transform (FFT). Itis applied on real measurement signals collected from anexperimental vibration system. The monitoring results indicatethat the proposed method improves the bearing faults diagnosisrelatively to other common techniques. Voir les détails
Mots clés : Vibration analysis, bearing Fault diagnosis, Hilbert Transform (HT), Envelope Analysis (EA), Fast Fourier Transform (FFT)
Etude Comparative des Techniques de Filtrage Actif Sélectif par le Référentiel Synchrone de Park d-q et l’Approche FMV
To minimize the total harmonic distortion (THD) and improve the power factor (PF), this paper presents a comparative study between two techniques of shunt power active filter (SPAF) by a selective action of harmonics. These two techniques are based on the SAPF of certain low frequency harmonics (5th and 7th) whose identification of the harmonics of references of the first is made by the axis synchronous d-q of the Park, and the second is done by the approach of self-tuning filter (STF) Thereafter, The active simultaneously filtering of the 5th and 7th harmonics of the current of load catches. The shapes of the signals and the THD values resulting from the results of digital simulations (Matlab-Simulink) elaborate the effectiveness and the best technique of this type of filtering. Voir les détails
Mots clés : PF, THD, Harmonics, SAPF, STF, d-q Park Synchronous Axis
L’impact d’une Charge Fortement Capacitive Sur la Qualitédu Filtrage d’un FAP Contrôlé Par un Filtre Multi-VariableHautement Sélectif
This article is devoted to the depollution of the electrical supply networks by shunt active power filter (SAPF). We start by studying a self tuning filter (STF) based on Concordia transformation. This transformation is based on the extraction of the references of harmonic currents in the Concordia axis to compensate network harmonic and by consequence, improve the quality of power system. Next, we present the influence of a strongly capacitive load on the quality of the filtering of a SAPF controlled by a STF approach. This influence is validated by numerical simulations under Matlab-Simulink environment of a system of power PD3 a diode debited in a strongly capacitive load this results prove the major influence of this types of load in filtering quality. Voir les détails
Mots clés : SAPF, harmonic, STF, System of Power PD3, Quality of Energy, Strongly Capacitive Load, Concordia transformation
Modeling, control and fault diagnosis of an isolated wind energy conversion system with a self-excited induction generator subject to electrical faults
In this paper, a contribution to modeling and fault diagnosis of rotor and stator faults of a Self-ExcitedInduction Generator (SEIG) in an Isolated Wind Energy Conversion System (IWECS) is proposed. In orderto control the speed of the wind turbine, while basing on the linear model of wind turbine system about aspecified operating point, a new Fractional-Order Controller (FOC) with a simple and practical designmethod is proposed. The FOC ensures the stability of the nonlinear system in both healthy and faulty conditions.Furthermore, in order to detect the stator and rotor faults in the squirrel-cage self-excited inductiongenerator, an on-line fault diagnostic technique based on the spectral analysis of stator currents ofthe squirrel-cage SEIG by a Fast Fourier Transform (FFT) algorithm is used. Additionally, a generalizedmodel of the squirrel-cage SEIG is developed to simulate both the rotor and stator faults taking iron loss,main flux and cross flux saturation into account. The efficiencies of generalized model, control strategyand diagnostic procedure are illustrated with simulation results. Voir les détails
Mots clés : Wind energy conversion systems, fault detection and diagnosis, SEIG, Fractional-Order Controllers
Contribution to the Fault Diagnosis of a Doubly Fed Induction Generator for a Closed-loop Controlled Wind Turbine System Associated with a Two-level Energy Storage System
In this article, a contribution to the fault diagnosis of adoubly fed induction generator for a closed-loop controlled wind turbinesystem associated with a two-level energy storage system usingan on-line fault diagnostic technique is proposed. This technique isproposed to detect the rotor fault in the doubly fed induction generatorunder non-stationary conditions based on the spectral analysis of statorcurrents of the doubly fed induction generator by an adaptive fastFourier transform algorithm. Furthermore, to prevent system deterioration,a fractional-order controller with a simple design method isused for the control of the whole wind turbine system. The fractionalordercontroller ensures that the system is stable in both healthy andfaulty conditions. Additionally, to improve the production capacityunder wind speed fluctuations and grid demand changes, a two-levelenergy storage system consisting of a supercapacitor bank and leadacidbatteries is proposed. The obtained simulation results show thatthe objectives of the fault diagnosis procedure and control strategyare reached. Voir les détails
Mots clés : Wind energy conversion systems, adaptive Fast Fourier transform, doubly fed induction generator, fault detection and diagnosis, fractional-order control, two-level energy storage system
Etude comparative entre trois techniques de filtrage actif parallèle sélectif
Dans le présent travail, nous présentons une étude comparativeentre trois techniques de filtrage actif parallèle sélectif desharmoniques, afin d’améliorer, le facteur de puissance du réseauélectrique FP. Ces trois techniques sont la théorie des puissancesinstantanées (P-Q), le référentiel synchrone de Park (d-q) etl’approche des filtres multi variables (FMV). Le principe de chaquetechnique est d’extraire les harmoniques de références du courant decharge, sélectivement ou simultanément. Généralement lesharmoniques en questions sont de basses fréquences et d’ordre 5 et7. L’objectif est que le courant du réseau ne contient pas lesharmoniques désirés à filtrés. Les formes d’ondes et les valeurs desTHD du courant de réseau avant et après le filtrage actif parallèlesélectif des harmoniques 5 et 7 issues des résultats de simulationsnumériques sous l’environnement Matlab/Simulink mettent enévidence l’efficacité et la meilleure des trois techniques élaborées. Voir les détails
Mots clés : PF, FAP, harmonique, P-Q, d-q, FMV, MLI, THD
Recherche de l'efficacité de la barrière isolante dans un système pointe-barrière isolante-plan.
L'objectif de ce travail est l'étude par simulation numérique de l'efficacité de la barrière isolante en fonction de ses dimensions géométriques et sa position dans l'intervalle inter-électrodes en considérant deux cas:-absence de la décharge électrique;-présence de la décharge électrique. Voir les détails
Mots clés : champ électrique, élements finis, efficacité, système pointe plan, arc électrique, claquage
Etude Comparative des Techniques de Filtrage Actif Sélectif Par le Référentiel Synchrone de Park d-q et l’Approche FMV
Cet article, présente une étude comparative entre deux techniques de filtrage actif parallèle par action sélective des harmoniques, afin de minimiser le facteur de distorsion harmonique totale THD, et par conséquence améliorer, le facteur de puissance FP. Les deux techniques sont basées sur le FAP de certaines harmoniques de basses fréquences 5 et 7, dont l’identification des harmoniques de références de la première se fait par le référentiel synchrone de Park dq, et la deuxième se fait par l’approche du Filtre Multi-Variable FMV. Le filtrage actif sélectif des harmoniques du courant de la charge 5 et 7 prises simultanément. Les formes des signaux et les valeurs des THD issues des résultats de simulations numériques (Matlab-Simulink) élaborés mettent en évidence l’efficacité et la meilleure technique de ce type de filtrage. Voir les détails
Mots clés : FP, THD, harmoniques, FMV, référentiel synchrone de Park d-q, FAP
Impact Majeur du Condensateur de Filtrage sur la Qualité d’un Filtre Actif Parallèle Contrôlépar l’Approche d’un FMV
Dans cet article, nous présentons l’impact majeurd’un condensateur de filtrage sur la qualité du filtrage d’unFiltre actif parallèle FAP contrôlé par une technique évoluéedénommée filtre multi-variable FMV, ce dernier se base sur latransformée de Concordia, et fait l’extraction sélective ou globaledes courants harmoniques de références, et par conséquencefaisant leur filtrage globale des ces harmoniques, par unecommande approprié de l’onduleur de tension, soit hystérésis ouMLI, on fait l’injection des courants harmonique au réseau à finde minimiser le taux de distorsion harmonique et parconséquences amélioré son facteur de puissance de réseauxélectrique. Les résultats de simulation numérique dansl’environnement Matab-Simulink d’un système de puissance PD3à diode débité sur une charge contient un grand condensateur defiltrage montrent bien l’impact majeur de cette condensateur surla qualité du courant du réseau filtré. Voir les détails
Mots clés : FAP, harmoniques, FMV, Système de Puissance PD3, Facteur de Puissance, MLI, Hystérises, Condensateur de Filtrage, Filtrage Globale