Passive control of tubes by crosscorrelation of ambient noisefields
Type : Article de conférence
Auteur(s) : , , , ,
Année : 2012
Domaine : Physique
Conférence: IEEE ultrasonics symposium
Lieu de la conférence:
Résumé en PDF :
Fulltext en PDF :
Mots clés : Green function, ambiant noise, cross corrélation, tube, flow fluide
Auteur(s) : , , , ,
Année : 2012
Domaine : Physique
Conférence: IEEE ultrasonics symposium
Lieu de la conférence:
Résumé en PDF :
Fulltext en PDF :
Mots clés : Green function, ambiant noise, cross corrélation, tube, flow fluide
Résumé :
The tube or pipeline are used for the routing of the uids such asgas, oil or water. The tubes deteriorate during its life. This dete-rioration can reveal defects, from where need for controlling of suchstructure. It is interesting to be able to detect damages in tubes byusing a passive control method. The goal of this work is to show inexperiments the possibility of using the function of cross correlation,between tow signals of noise, in order to make a passive control of thetubular structures. The noise in the tube was generated by ow of uid.The reproducibility of the function of cross correlation and its sensi-tivity to the presence of a defect, were checked for several frequenciesin the frequently band of [200 Hz, 35kHz]. Moreover, the movementof the uid in the tube generates a temperature variation; the inu-ence of this temperature variation on the cross correlation function wasstudied.